Ex Aluminum Enclosures

GBAEX enclosures are based on the proven GBA aluminium platform and configured for explosion-protected projects with external earthing and nameplate marking. The range supports Ex e (increased safety) and Ex i (intrinsic safety) concepts with project-specific certification scope.

The matrix includes 34 sizes from 58 x 64 x 34 mm up to 600 x 310 x 180 mm, with PDF drawings and 3D STEP models available for engineering.

Weight

150 to 12000 g

Material

Aluminium AlSi12

Color

RAL7001, special colours on request

Size Range

58 x 64 x 34 to 600 x 310 x 180 mm

HS Code

85369030

Special Options

Ex e / Ex i, U/K versions

Additional Information

Material Composition

Aluminium platform based on GBA

Protection

Ex-oriented construction for hazardous area projects

Surface

Powder Coated (structured, silky & shiny)

Primary Use Case

Explosion-protected machine and process areas

Operating Temperature

According to final approved project components

Protection Rating

IP66 (DIN EN 60529)

Earthing

Yes, external earthing connection on lower part

RoHS Compliance

RoHS EU Directive 2011/65/EU

REACH Compliance

REACH Regulation 1907/2006/EC

Compatibility

Mechanical platform continuity with GBA size family (project release dependent)

XINDUX Items Length (mm) Width (mm) Height (mm) Weight (g) Mounting Plate Hinges 3D Models
GBAEX000586434 58 64 34 150 Download
GBAEX000758057 75 80 57 350 Download
GBAEX000986434 98 64 34 200 Download
GBAEX010010081 100 100 81 650 Download
GBAEX012212081 122 120 81 1000 Download
GBAEX012212090 122 120 90 1050 Download
GBAEX001258057 125 80 57 450 Download
GBAEX014014091 140 140 91 1350 Download
GBAEX001506434 150 64 34 300 Download
GBAEX016010081 160 100 81 850 Download
GBAEX016016091 160 160 91 1600 Download
GBAEX001758057 175 80 57 600 Download
GBAEX180180100 180 180 100 2100 Download
GBAEX020014090 200 140 90 1650 Download
GBAEX200230113 200 230 113 2800 Download
GBAEX200230180 200 230 180 4050 Download
GBAEX022012081 220 120 81 1500 Download
GBAEX022012091 220 120 91 1650 Download
GBAEX002508057 250 80 57 850 Download
GBAEX026016091 260 160 91 2300 Download
GBAEX280180100 280 180 100 2800 Download
GBAEX280230110 280 230 110 3350 -
GBAEX330230111 330 230 111 3800 Download
GBAEX330230180 330 230 180 3600 Download
GBAEX036012080 360 120 80 2050 Download
GBAEX036016090 360 160 90 3000 Download
GBAEX400230110 400 230 110 5400 Download
GBAEX400230180 400 230 180 6150 Download
GBAEX400310110 400 310 110 7100 Download
GBAEX400310180 400 310 180 8850 Download
GBAEX056016090 560 160 90 4000 -
GBAEX600230110 600 230 110 7250 -
GBAEX600310110 600 310 110 9250 Download
GBAEX600310180 600 310 180 12000 Download

FAQs

U is the Ex-certified empty housing. K is the populated Ex terminal housing with project-specific internal equipment.

34 sizes, from 58 × 64 × 34 mm up to 600 × 310 × 180 mm.

IP66 is standard for GBAEX housings.

U = Ex-certified empty housing; K = populated Ex terminal housing with project-specific internal equipment.

The range supports Ex e (increased safety) and Ex i (intrinsic safety) depending on project requirements.

Yes, GBAEX includes an external earthing connection on the lower part as part of the Ex-oriented design.

Yes, nameplate included as part of the Ex execution.

A broad Ex matrix exists, but final release depends on certification scope and selected configuration.

All attached and internal components must comply with the applicable Ex approvals for the final assembly.

Yes, K versions can be configured with terminal systems, entries, and internal arrangement according to approved project design.

Yes, matrix models are provided with PDF and STEP data for faster layout/documentation work.

150 to 12,000 g depending on model.

Model dependent, matrix indicates mounting plate and hinge availability per item.

Documentation scope and configuration follow the project approval path; XINDUX aligns the enclosure setup to the required Ex concept and certification package.

Yes, entries and internal arrangement can be defined project-wise (especially for K versions).

Zone/concept (Ex e or Ex i), U vs K, required entries/terminals, approval scope, earthing/identification needs, and any internal component constraints (approved parts only).

Yes, availability is listed as in stock (standard matrix).

Any component or entry changes must be evaluated against the Ex approvals and the approved project design before release.

The datasheet states nameplate included; additional marking/identification is typically handled within the project-specific Ex documentation/configuration scope.

Freeze the approval scope early, supply the entry layout + terminal list up front, and keep all internal components aligned with project approvals.

Frequently Asked Questions

Our High-Voltage Circuit Breaker is certified to IEC 62271 and IEEE C37 standards, ensuring compliance with international safety and performance requirements. Additional regional certifications include CE, UL, and CCC marks for global market acceptance.

Yes, we offer comprehensive OEM customization services including voltage ratings, mounting configurations, control interfaces, and branding options. Our engineering team works closely with clients to develop tailored solutions that meet specific application requirements.

Standard configurations are typically available within 4–6 weeks. Custom orders require 8–12 weeks depending on specification complexity. We maintain strategic inventory for common models to support urgent project requirements.

XINDUX provides comprehensive global technical support through our network of regional service centers. This includes installation guidance, commissioning assistance, preventive maintenance programs, and 24/7 emergency response capabilities across all major markets.

You may also like